Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
CoDAS ; 35(6): e20220111, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1528434

ABSTRACT

RESUMO Objetivo Investigar a queixa de dificuldade de inteligibilidade na presença de ruído, em sujeitos sem perda auditiva e compará-la com o desempenho em um teste de fala no ruído. Método A casuística foi constituída por 39 sujeitos de 18 a 59 anos e 11 meses foram divididos em quatro grupos em função da década de vida. Estes foram submetidos à audiometria, timpanometria, testes de processamento auditivo, mini exame do estado mental, autorrelato da percepção auditiva com o Pt-AIADH e a um teste de sentenças no silêncio e no ruído. Resultados Todos os grupos pontuaram para os domínios do Pt-AIADH, com maior pontuação média para o domínio de inteligibilidade no ruído. Houve diferenças entre o G18 vs G40, G18 vs G50, e G30 vs G50 para a autopercepção auditiva na inteligibilidade no ruído; e diferenças entre o G18 e os demais grupos no teste de fala com ruído, com menor relação sinal-ruído para os adultos mais velhos. Houve correlação moderada e significativa para a inteligibilidade no ruído e o teste de fala no ruído. Conclusão Normo-ouvintes de todas as faixas etárias estudadas apresentaram queixa de inteligibilidade no ruído. Quanto maior a dificuldade auditiva neste domínio pior o desempenho no teste de fala com ruído, sendo mais significativo em adultos de meia idade.


ABSTRACT Purpose To investigate complaints of difficulty understanding speech in the presence of noise in subjects without hearing loss and their performance on a speech-in-noise test. Methods Thirty-nine subjects aged 18 to 59 years and 11 months were divided into four groups according to their decade of life. They underwent audiometry, tympanometry, auditory processing tests, the Mini-Mental State Examination, a self-report on auditory perception combined with the Amsterdam Inventory for Auditory Disability and Handicap (Pt-AIADH), and a sentence test in silence and in noise. Results All groups scored high on the Pt-AIADH domains, with the highest average score obtained for the noise intelligibility domain. There were differences between G18 vs. G40, G18 vs. G50, and G30 vs. G50 for auditory self-perception in noise intelligibility, and differences between the youngest and all other groups on the speech-in-noise test in particular, with a lower signal-to-noise ratio for older adults. We also identified a moderate and significant correlation between intelligibility in noise and the speech-in-noise test. Conclusion Normal hearers of all age groups complained of intelligibility in noise. We found that the higher an individual's auditory difficulty in this domain, the worse their performance on the speech-in-noise test; this is especially true for middle-aged adults.

2.
Distúrb. comun ; 34(2): e54784, jun. 2022.
Article in Portuguese | LILACS | ID: biblio-1396882

ABSTRACT

Introdução: Ouvintes de rádio e podcast deduzem traços de personalidade quando ouvem os apresentadores, a partir exclusivamente da fala desses profissionais. Objetivo: Identificar os fatores que interferem na atribuição de características de personalidade a partir da voz, e discutir como o julgamento do público pode modificar a performance dos apresentadores de rádio e podcast. Método: Por meio de um levantamento bibliográfico inicial, foram apresentadas referências bibliográficas sobre pesquisas de julgamento de voz, considerando aspectos socioculturais e de gênero, e a interferência dos estereótipos no comportamento e na fala dos indivíduos. Resultados: Pesquisas de julgamento de personalidade pela voz indicam que a avaliação dos ouvintes se baseia nos traços de personalidade mais marcantes e valorizados socialmente, ou seja, os estereótipos. Considerando que os mesmos valores são compartilhados também pelos comunicadores, é possível supor que esses procurem imprimir na sua fala características que agradem ao público. Conclusão: A tentativa de corresponder aos estereótipos parece resultar na padronização da fala dos comunicadores de rádio e podcast.


Introduction: Radio and podcast listeners deduce personality traits when they listen to presenters, exclusively from the speech of these professionals. Objective: To identify the factors that interfere in the attribution of personality characteristics based on the voice, and to discuss how the audience ́s judgment can modify the performance of radio and podcast presenters. Methods: Through initial bibliographic survey, bibliographical references on voice judgment research were presented, considering sociocultural and gender aspects, and the interference of stereotypes in the behavior and speech of individuals. Results:Surveys of personality judgment by voice indicate that the listeners; assessment is based on the most striking and socially valued personality traits: the stereotypes. Considering that the same values are also shared by communicators, it is possible to suppose that they try imprinting characteristics in their speech that please the public. Conclusion: The attempt to correspond to stereotypes seems to result in the standardization of the speech of radio and podcast communicators.


Introducción: Los oyentes de radio y podcasts deducen rasgos de personalidad cuando escuchan a los presentadores, exclusivamente del discurso de estos profesionales. Objetivo: Identificar los factores que interfieren en la atribución de características de personalidad basadas en la voz y discutir cómo el juicio de la audiencia puede modificar el desempeño de los presentadores de radio y podcast. Metodos:Através de un estudio bibliográfico inicial, se presentaron referencias bibliográficas sobre investigaciones de juicio de voz, considerando aspectos socioculturales y de género, y la interferencia de estereotipos en la conducta y el habla de los individuos. Resultados: Las encuestas de juicio de personalidad por voz indican que la valoración de los oyentes se basa en los rasgos de personalidad más llamativos y valorados socialmente, es decir, los estereotipos. Teniendo en cuenta que los mismos valores también los comparten los comunicadores, es posible suponer que intentan imprimir en su discurso características que agraden al público. Conclusión: El intento de corresponder a los estereotipos parece resultar en la estandarización del habla de los comunicadores de radio y podcast.


Subject(s)
Humans , Male , Female , Personality , Speech Perception , Stereotyping , Communication , Judgment , Radio , Webcasts as Topic
3.
Audiol., Commun. res ; 27: e2661, 2022. tab
Article in Portuguese | LILACS | ID: biblio-1420255

ABSTRACT

RESUMO Objetivo Verificar a correlação das diferentes médias tonais (tritonal, quadritonal e octonal) com o Índice Percentual de Reconhecimento de Fala e com a desvantagem auditiva. Métodos Participaram do estudo 56 sujeitos, distribuídos em dois grupos, com configuração audiométrica descendente: Grupo 1 (G1) - 28 sujeitos com média tritonal igual ou inferior a 25 dBNA e Grupo 2 (G2) - 28 sujeitos com média tritonal pior que 25 dBNA (G2), sendo pareados quanto ao gênero e idade (p= 0,544). Todos foram submetidos à audiometria tonal liminar, Índice Percentual de Reconhecimento de Fala (IPRF) com lista monossilábica de palavras gravadas, medidas de imitância acústica e ao questionário Hearing Handicap Inventory for Adults. A análise de correlação foi realizada entre as médias de três frequências (M3), de quatro frequências (M4) e de oito frequências (M8) com o IPRF e com a desvantagem auditiva, utilizando o teste de correlação de Spearman, sendo o nível de significância considerado <0,05 (5%). Resultados Evidenciou-se correlação estatisticamente significativa do IPRF com a M8, para o G1, e do IPRF com M4 e M8, para o G2. Observou-se tendência à significância, tanto para o G1, como para o G2, em relação à M8, quando correlacionada com a desvantagem auditiva, demonstrando que analisar as oito frequências do audiograma (frequências mais agudas que 4000 Hz) parece possibilitar maior compreensão em relação à desvantagem auditiva do paciente. Conclusão Houve correlação estatisticamente significativa do IPRF com a M8, nos dois grupos, denotando uma redução no desempenho do IPRF, com o aumento da média, considerando as oito frequências. A M8 refletiu melhor a desvantagem auditiva causada pela perda auditiva, no G1.


ABSTRACT Purpose To verify the correlation of different tonal means (tritonal, quadritonal and octanol) with the Percentage Index of Speech Recognition and with hearing disadvantage. Methods 56 subjects participated in the study, distributed into two groups, with descendant audiometric configuration: Subjects with tritonal average equal to or less than 25 dB HL(G1) and subjects with a tritone average worse than 25 dB HL(G2), being matched for sex and age (p=0.544). All were safe by Threshold Tone Audiometry, Speech Recognition Percentage Index (IPRF) with a list of keywords, Acoustic I Measures and the Elearing Handicap Inventory for Adults. The correlation analysis was performed between the averages, of three frequencies (M3), of four frequencies (M4) and of eight frequencies (M8) with the IPRF and with auditory disadvantage, using the Spearman correlation test, the significance level being considered <0.05 (5%). Results There was a statistically significant correlation of the IPRF with M8 , for G1, and the IPRF with M4 and M8, for G2. There was a tendency towards significance, both for G1 and G2, in relation to M8 when correlated with hearing impairment, demonstrating that analyzing the eight frequencies of the audiogram (frequencies higher than 4000 Hz) seems to allow a greater understanding of the patient's hearing handicap. Conclusion There was a statistically significant correlation between the IPRF and M8, in both groups, denoting a reduction in the performance of the IPRF, with an increase in the mean, considering the eight frequencies. M8 better reflected the hearing disadvantage caused by the hearing loss in G1.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Audiometry, Pure-Tone/methods , Auditory Perception , Speech Acoustics , Voice Recognition , Hearing Loss/physiopathology
4.
CoDAS ; 33(1): e20180324, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1249593

ABSTRACT

RESUMO Objetivo Avaliar como as vias auditivas codificam e diferenciam as sílabas plosivas [ga],[da] e [ba], por meio do potencial evocado auditivo Frequency Following Response (FFR), nas crianças em desenvolvimento típico. Método Vinte crianças (6-12 anos) foram avaliadas por meio do FFR para estímulos [ga],[da] e [ba]. Os estímulos foram compostos por seis formantes, sendo diferenciados na transição F2 e F3 (porção transiente). Os demais formantes foram idênticos nas três sílabas (porção sustentada). Foram analisadas latências de 16 ondas que compõe a porção transiente do estímulo (<70ms) e latências de 21 ondas da porção sustentada (90-160ms) nas respostas neurais obtidas para cada uma das sílabas. Resultados As respostas eletrofisiológicas registradas por meio do FFR demonstraram que as latências da porção transiente da resposta neural foram diferentes nas três silabas evocadas. Além disso, os valores de latência das ondas da porção transiente foram aumentando progressivamente, sendo [ga]<[da]<[ba]. Já na porção sustentada da resposta, não houve diferenças significantes nas latências das ondas que compõe essa porção. Conclusão O FFR mostrou-se uma ferramenta eficiente na investigação da discriminação subcortical de diferenças acústicas dos sons de fala, uma vez que demonstrou diferentes resposta eletrofisiológica para três silabas evocadas. Na porção transiente (consoantes) foram observadas mudanças de latência e na porção sustentada (vogal) não houve diferenças entre as latências para os três estímulos. Esses resultados demonstram a capacidade neural de distinção entre características acústicas dos estímulos [ga],[da],[ba].


ABSTRACT Purpose To evaluate how the auditory pathways encode and discriminate the plosive syllables [ga], [da] and [ba] using the auditory evoked Frequency-following Response (FFR) in children with typical development. Methods Twenty children aged 6-12 years were evaluated using the FFR for the [ga], [da] and [ba] stimuli. The stimuli were composed of six formants and were differentiated in the F2 to F3 transition (transient portion). The other formants were identical in the three syllables (sustained portion). The latencies of the 16 waves of the transient portion (<70ms) and of the 21 waves of the sustained portion (90-160ms) of the stimuli were analyzed in the neural responses obtained for each of the syllables. Results The transient portion latencies were different in the three syllables, indicating a distinction in the acoustic characteristics of these syllables through their neural representations. In addition, the transient portion latencies progressively increased in the following order: [ga] <[da] <[ba], whereas no significant differences were observed in the sustained portion. Conclusion The FFR proved to be an efficient tool to investigate the subcortical acoustic differences in speech sounds, since it demonstrated different electrophysiological responses for the three evoked syllables. Changes in latency were observed in the transient portion (consonants) but not in the sustained portion (vowels) for the three stimuli. These results indicate the neural ability to distinguish between acoustic characteristics of the [ga], [da] and [ba] stimuli.


Subject(s)
Humans , Child , Speech Perception , Phonetics , Acoustic Stimulation , Acoustics , Evoked Potentials, Auditory, Brain Stem , Hearing
5.
Audiol., Commun. res ; 26: e2517, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1350156

ABSTRACT

RESUMO O objetivo do trabalho foi criar um protocolo de treinamento auditivo e cognitivo para idosos e analisar a sua eficácia. O estudo foi realizado em três etapas: (1) seleção de materiais, compreendendo materiais existentes e outros confeccionados pelos autores; (2) análise de juízes especialistas, para consenso quanto às habilidades avaliadas e tipo de treinamento; (3) aplicação do protocolo em um caso clínico, com realização de uma bateria de testes para avaliação pré e pós-intervenção, consistindo em avaliação cognitiva e auditiva (comportamental e eletrofisiológica). Foi possível a estruturação do protocolo de acordo com as sugestões das juízas especialistas, o que gerou uma nova proposta de treinamento auditivo e cognitivo com 39 tarefas, dispostas em seis sessões. Com a aplicação do protocolo no caso clínico, observaram-se modificações positivas nos dois aspectos treinados. A nova proposta terapêutica foi concluída e aplicada. O sujeito do caso clínico obteve melhoras pós-intervenção e a eficácia foi verificada por meio dos testes comportamentais de processamento auditivo central, de rastreio cognitivo e do potencial evocado auditivo de longa latência.


ABSTRACT The objective of the work was create an auditory and cognitive training protocol for the elderly and to analyze its effectiveness. This study was carried out in three stages: (1) Selection of materials, composed of existing materials and others made by the authors, (2) Analysis of expert judges, for consensus regarding the assessed skills and type of training, and (3) Application of the protocol in a clinical case, with a battery of tests for pre-and post-intervention, composed of cognitive and auditory assessment (behavioral and electrophysiological). It was possible to structure the protocol according to the suggestions of the expert judges, which generated a new proposal for auditory and cognitive training with 39 tasks arranged in six sessions. With the application of the protocol in the clinical case, it was possible to observe positive changes in both trained aspects. The new therapeutic proposal has been completed and applied. The clinical case has shown improvement after the intervention, and the effectiveness was verified through behavioral tests of central auditory processing, cognitive screening, and long-latent auditory evoked potential.


Subject(s)
Humans , Female , Aged , Aged, 80 and over , Auditory Perception , Speech Perception , Hearing Tests , Neuropsychological Tests , Evoked Potentials, Auditory , Neuronal Plasticity
6.
Braz. j. otorhinolaryngol. (Impr.) ; 86(2): 209-216, March-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1132583

ABSTRACT

Abstract Introduction: Deficient auditory processing can cause problems with speech perception and affect the development and evolution of reading skills. The efferent auditory pathway has an important role in normal auditory system functions like speech-in-noise perception, but there is still no general agreement on this. Objective: To study the performance of the efferent auditory system in a group of children with reading impairment in comparison with normal reading and evaluation of its relationship with speech-in-noise perception. Methods: A total of 53 children between the ages of 8-12 years were selected for the study of which 27 were with reading impairment and 26 were normal reading children. Transient evoked otoacoustic emissions suppression and auditory recognition of words-in-noise test were performed for all the children. Results: The average amplitude of transient evoked otoacoustic emissions suppression showed a significant difference between the two groups in the right (p = 0.004) and in the left ear (p = 0.028). Assessment of the relationship between transient evoked otoacoustic emissions suppression and monaural auditory recognition of words-in-noise scores showed a significant moderate negative relationship only in the right ear (p = 0.034, r = −0.41) of the normal reading children. Binaural auditory recognition of words-in-noise scores were significantly correlated with the amplitude of transient evoked otoacoustic emissions suppression in the right ear (p < 0.001, r = −0.75) and in the left ear (p < 0.001, r = −0.64) of normal reading children. In the reading impaired group, ?a weaker correlation was observed between binaural auditory recognition of words-in-noise scores and transient evoked otoacoustic emissions suppression in the right (p = 0.003, r = −0.55) and in the left ear (p = 0.012, r = −0.47). Conclusions: Transient evoked otoacoustic emissions suppression pattern in the reading impaired group was different compared with normal reading children, and this difference could be related to efferent system performance. Words-in-noise scores in children with impaired reading were lower than in normal reading children. In addition, a relationship was found between transient evoked otoacoustic emissions suppression and words-in-noise scores in both normal and impaired reading children.


Resumo Introdução: O processamento auditivo deficiente pode causar problemas na percepção da fala e afetar o desenvolvimento e a evolução das habilidades de leitura. A via auditiva eferente tem um papel importante nas funções do sistema auditivo normal, como a percepção da fala no ruído, mas ainda não há um consenso sobre isso. Objetivo: Estudar o desempenho do sistema auditivo eferente em um grupo de crianças com dificuldade de leitura em comparação às com leitura normal e avaliação de sua relação com a percepção da fala no ruído. Método: Foram selecionadas para o estudo 53 crianças entre oito e 12 anos, das quais 27 tinham dificuldade de leitura e 26 apresentavam leitura normal. A avaliação por emissões otoacústicas evocadas transientes e o teste auditory recognition of words-in-noise foram feitos em todas as crianças. Resultados: A amplitude média da supressão das emissões otoacústicas evocadas transientes mostrou diferença significante entre os dois grupos na orelha direita (p = 0,004) e esquerda (p = 0,028). A avaliação da relação entre a supressão das emissões otoacústicas evocadas transientes e os escores monoaurais do teste auditory recognition of words-in-noise mostrou uma relação negativa moderadamente significante apenas na orelha direita (p = 0,034, r = -0,41) das crianças com leitura normal. Os escores binaurais do auditory recognition of words-in-noise foram significantemente correlacionados com a amplitude de supressão das emissões otoacústicas evocadas transientes na orelha direita (p < 0,001, r = -0,75) e na orelha esquerda (p < 0,001, r = -0,64) das crianças com leitura normal. No grupo com dificuldade de leitura, uma correlação mais fraca foi observada entre os escores binaurais do auditory recognition of words-in-noise e supressão das emissões otoacústicas evocadas transientes, na orelha direita (p = 0,003, r = -0,55) e na esquerda (p = 0,012, r = -0,47). Conclusões: O padrão de supressão das emissões otoacústicas evocadas transientes no grupo com dificuldade de leitura foi diferente em comparação com as crianças com leitura normal e essa diferença pode estar relacionada ao desempenho do sistema eferente. Os escores de palavras no ruído em crianças com dificuldade de leitura foram menores do que nas crianças com leitura normal. Além disso, foi encontrada uma relação entre a supressão das emissões otoacústicas evocadas transientes e os escores de palavras no ruído tanto em crianças com leitura normal quanto nas com dificuldade de leitura.


Subject(s)
Humans , Male , Female , Child , Auditory Pathways/physiology , Speech Perception/physiology , Evoked Potentials, Auditory, Brain Stem/physiology , Otoacoustic Emissions, Spontaneous/physiology , Dyslexia/physiopathology , Efferent Pathways/physiology , Acoustic Stimulation , Case-Control Studies , Noise
7.
Audiol., Commun. res ; 25: e2280, 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1131778

ABSTRACT

RESUMO Objetivo Correlacionar o desempenho de usuários de implante coclear unilateral em testes de reconhecimento de fala, no silêncio e no ruído, com as respostas ao questionário de autoavaliação Hearing Implant Sound Quality Index (HISQUI19) e correlacionar o desempenho em testes de reconhecimento de fala com o tempo de uso do dispositivo e a orelha implantada. Métodos Participaram 27 usuários de implante coclear unilateral com deficiência auditiva pós-lingual, que faziam uso do dispositivo há, pelo menos, um ano e apresentavam limiar tonal em campo livre menor que 40 dBA. Todos os participantes foram submetidos à audiometria tonal em campo livre, responderam ao questionário HISQUI19 e realizaram testes de reconhecimento de fala no silêncio e no ruído. Resultados As respostas ao questionário foram comparadas com os testes de reconhecimento de fala no silêncio e no ruído e não houve diferença estatisticamente significativa. Na comparação em relação ao tempo de uso do implante coclear, só houve diferença estatisticamente significativa para o teste de reconhecimento de fala no silêncio. Não houve correlação significativa entre o reconhecimento de fala e a orelha implantada. Conclusão independentemente do tempo de uso do dispositivo e/ou do desempenho nos testes de reconhecimento de fala, muitos participantes classificaram a qualidade sonora do implante coclear como moderada. A aplicação de testes que possibilitem mensurar a satisfação e o benefício dos usuários deve fazer parte da rotina clínica dos centros de implante.


ABSTRACT Purpose To correlate the performance of unilateral cochlear implant users in speech recognition tests, in quiet and noise, with the answers to the Hearing Implant Sound Quality Index (HISQUI19) self-assessment questionnaire; also, to correlate the performance in speech recognition tests with the time of CI use and the implanted ear. Methods A total of 27 unilateral CI users with postlingual hearing loss, who had been using the device for at least one year and had free-field pure-tone threshold lower than 40 dBA, participated in the study. All the participants were submitted to free-field pure-tone audiometry, answered the HISQUI19 questionnaire, and took speech recognition tests in quiet and noise. Results The answers to the questionnaire were compared with the speech recognition tests in quiet and noise; there was no statistically significant difference. When comparing with the time of CI use, there was a statistically significant difference only for the speech recognition test in quiet. There was no significant correlation between speech recognition and the implanted ear. Conclusion Regardless of the time of CI use and/or performance in the speech recognition tests, many participants classified the sound quality of their cochlear implant as moderate. Administering tests to measure the users' level of satisfaction and benefit should integrate the clinical routine in implantation centers.


Subject(s)
Humans , Speech Discrimination Tests , Speech Perception , Cochlear Implantation , Auditory Threshold , Diagnostic Self Evaluation , Hearing Loss
8.
Rev. CEFAC ; 22(5): e7720, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136503

ABSTRACT

ABSTRACT Purpose: to investigate the magnitude of the modulation masking release in sentence recognition as a function of compression level and modulation rate. Methods: sentences of the Brazilian Portuguese version of the Hearing in Noise Test sentences were used as stimulus. The sentence recognition thresholds were established as a function of speech compression level (0%, 33%, and 50%) in steady and modulated noise at different modulation rates (4, 10, 32 Hz). The analysis of variance was performed for repeated measures, using the 5% significance level. Results: sentence recognition thresholds were higher for higher compression levels in the different types of noise. However, thresholds were smaller for modulated noises. Also, the magnitude of modulation masking release decreased as speech compression level increased. Nevertheless, no difference was observed in compressed speech between different noise modulation rates, in relation to the speech compression level. Conclusion: the magnitude of the modulation masking release decreased as the speech time-compression increased. Also, the reductions in modulation masking release, in relation to the speech time-compression level, did not differ between the masking-noise modulation rates (4, 10, and 32 Hz).


RESUMO Objetivo: investigar a magnitude do benefício da modulação do mascaramento no reconhecimento de sentenças, em função do nível de compressão temporal da fala e da taxa de modulação do ruído. Métodos: foram utilizadas sentenças do Hearing in Noise Test versão Português do Brasil. Foram determinados os limiares de reconhecimento das sentenças em função do nível de compressão temporal da fala (0%, 33% e 50%) em presença de ruído estável e modulado, em diferentes taxas de modulação (4, 10, 32 Hz). Foi realizada uma análise de variância para medidas repetidas, adotando nível de significância de 5%. Resultados: os limiares de reconhecimento de sentenças foram mais elevados com o aumento do nível de compressão temporal nos diferentes tipos de ruídos, no entanto, foram menores em presença dos ruídos modulados. Além disso, a magnitude do benefício da modulação do mascaramento diminuiu com o aumento do nível de compressão temporal da fala. Contudo, não foi observada diferença na fala comprimida entre as diferentes taxas de modulação do ruído, em função do nível de compressão temporal da fala. Conclusão: a magnitude do benefício do mascaramento modulado diminuiu com o aumento da compressão temporal da fala e as reduções no benefício do mascaramento modulado em função do nível de compressão temporal da fala não diferiram entre as taxas de modulações do ruído mascarante (4 Hz, 10 Hz e 32 Hz).

9.
Audiol., Commun. res ; 23: e1979, 2018. tab
Article in Portuguese | LILACS | ID: biblio-983903

ABSTRACT

RESUMO Objetivo Investigar os efeitos dos processos cognitivos e do Índice de Inteligibilidade de Fala no reconhecimento de fala no ruído em idosos, com e sem alteração cognitiva, usuários de próteses auditivas. Métodos 34 idosos, de 64 a 87 anos, com perda auditiva neurossensorial simétrica de grau moderado, usuários de próteses auditivas, foram distribuídos em grupos de idosos sem (GA; n=21) e com (GB; n=13) evidências de alteração cognitiva. A fim de garantir que o ajuste das próteses auditivas estivesse adequado, realizou-se o mapeamento visível de fala amplificada e foram obtidos os indices de ínteligibilidade de fala. Os idosos foram submetidos a uma triagem cognitiva (10-CS) e ao teste Lista de Sentenças em Português. A avaliação constou da pesquisa do limiar de reconhecimento de sentenças no ruído. Esta pesquisa foi realizada em campo livre, na condição sem e com próteses auditivas. Para análise estatística, foram utilizados os testes de Qui-Quadrado e Mann-Whitney. O nível de significância adotado foi de 0,05. Resultados Não houve diferença significativa entre os índices de inteligibilidade de fala obtidos em ambos os grupos, tanto na condição com próteses auditivas, como na condição sem as próteses. Verificou-se que os idosos com e sem alteração cognitiva apresentaram o mesmo acesso aos sons da fala (SII), nas duas condições. Observou-se que os idosos sem alteração cognitiva apresentaram menor relação sinal/ruído média, para o reconhecimento de 50% das sentenças na presença de ruído tanto na condição sem próteses auditivas como na condição com próteses, do que aqueles com alteração cognitiva. Conclusão Idosos com melhor cognição apresentaram melhor reconhecimento de fala em condições de escuta difícil.


ABSTRACT Purpose Investigate the effects of cognitive processes and Speech Intelligibility Index (SII) in sentence recognition in noise among elderly users of hearing aids with and without cognitive disorders. Methods Study participants were 34 older adults, aged 64-87 years, with bilateral moderate sensorineural hearing loss, users of hearing aids for over a year. The individuals were divided into two groups: GA - without cognitive impairment (n=21) and GB - with cognitive impairment (n=13). In order to verify the adequate amplification of the hearing aids, participants of both groups underwent Visible Speech Mapping and had their Speech Intelligibility Indexes obtained. Subsequently, they were submitted to cognitive screening (10-CS) and the Brazilian Portuguese Sentence List Test. Evaluation consisted of a search for speech perception thresholds in noise (S/N ratio). This search was performed in free-field conditions first without and then with the hearing aids. Data were statistically analyzed at a significance level of 5% using the Chi-squared and Mann-Whitney tests. Results No statistically significant differences were observed between the SII results obtained in both groups either with or without hearing aids. These results demonstrate that the older individuals in the GA and GB present the same access to speech sounds with and without hearing aids. Individuals in the GA presented lower S/N ratio under both conditions. Conclusion Older individuals with better cognition present greater speech recognition in the presence of competitive noise.


Subject(s)
Humans , Aged , Aged, 80 and over , Speech Intelligibility , Cochlear Implants , Cognition , Noise , Speech Perception , Speech Reception Threshold Test , Chi-Square Distribution , Statistics, Nonparametric , Speech Recognition Software , Hearing Aids , Hearing Loss, Sensorineural
10.
Audiol., Commun. res ; 23: e1861, 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-983910

ABSTRACT

RESUMO Objetivo Investigar o efeito da idade no benefício da modulação do ruído mascarante (masking release) e no pós-mascaramento ( forward masking). Métodos Participaram da pesquisa jovens (média de idade de 18 anos e quatro meses) e idosos (média de idade de 64 anos e três meses) falantes nativos do Português Brasileiro e com audição normal. Mediante uso de sentenças da versão brasileira do Hearing in Noise Test, determinou-se, para ambos os grupos, limiares de reconhecimento em presença de ruído estável e em presença de ruído modulado em amplitude (10 Hz). Para a pesquisa do pós-macaramento, foram determinados limiares auditivos em intervalos de tempo de 4, 16, 64 e 128 milissegundos, após a interrupção do ruído. Para avaliar a normalidade dos resultados obtidos, foi aplicado o teste de Shapiro-Wilk. Nas variáveis em que a normalidade foi indicada, aplicou-se o teste t de Student para amostras independentes e nos casos em que a normalidade não foi encontrada, aplicou-se o teste de Mann-Whitney. Foi considerado o nível de significância de 5% Resultados Observou-se o benefício da modulação do mascaramento nos dois grupos. Porém, esse benefício foi menor para o grupo dos idosos (p-valor < 0,001). Na investigação do pós-mascaramento, houve diferença significativa entre os grupos, na média de limiares em 128 milissegundos, após a cessação do ruído (p-valor = 0,006). Conclusão O estudo mostra efeito da idade no benefício de modulação do ruído mascarante e no pós-mascaramento.


ABSTRACT Purpose The purpose of this study was to investigate the age-related effects of modulation masking release and forward masking. Methods Ten younger (mean age of 18.4) and ten older (mean age of 64.3) adults participated in the study. All participants were native speakers of Brazilian Portuguese with normal hearing. Sentences of the Brazilian version of the Hearing in Noise Test were used to obtain speech recognition thresholds in the presence of steady-state noise and amplitude-modulated noise (10 Hz). To investigate forward masking, auditory thresholds were determined at time intervals of 4, 16, 64, and 128 ms after noise interruption. The Shapiro-Wilk test was applied to evaluate the normality of the results. In the variables in which normality was indicated, the Student's t-test was applied for the independent samples, and the Mann-Whitney test was applied in cases where normality was not found. A significance level of 5% was adopted for all statistical analyses. Results Modulation masking release was present in both groups; however, it was significantly smaller in the elderly group. As for forward masking investigation, higher thresholds were obtained after noise interruption, and improved as the time interval between noise and stimulus presentation increased. Forward masking was higher in the elderly group, whit higher thresholds for the time interval of 128 ms. Conclusion An age-related effect was identified on modulation masking release and forward masking.


Subject(s)
Humans , Adult , Middle Aged , Perceptual Masking , Auditory Threshold , Speech Perception , Statistics, Nonparametric , Noise
11.
CoDAS ; 30(2): e20170030, 2018. tab
Article in Portuguese | LILACS | ID: biblio-890839

ABSTRACT

RESUMO Objetivo Elaborar uma lista de pseudopalavras em Português Brasileiro para avaliação da habilidade de discriminação auditiva de sons da fala e investigar a consistência interna dos itens de teste e o efeito do ano escolar sobre o desempenho na discriminação. Método Participaram 60 escolares de 3º (N=14), 4º (N=24) e 5º anos (N=22) do Ensino Fundamental (60% meninas) entre 8 anos e 2 meses e 11 anos e 8 meses (99 a 136 meses; M=120,05; DP=10,26), com média de rendimento escolar=7,21 pontos (DP=1,23; mínimo 5,0; máximo 10). Elaboraram-se 48 pares mínimos de pseudopalavras, com estrutura do Português Brasileiro e oponência de apenas um fonema. As repostas dos participantes (se os elementos dos pares eram iguais ou diferentes) foram anotadas e analisadas. Calculou-se o Coeficiente Alfa de Cronbach, o Coeficiente de Correlação de Spearman e o Teste de Bonferroni, com nível de significância de 0,05. Resultados A análise da consistência interna indicou a retirada de 20 pares. Vinte e oito resultantes mostraram boa consistência interna (α=0,84). O máximo de respostas corretas de discriminação dos estudantes foi 34, o mínimo = 16, a média = 30,79 (DP = 3,68). Não foram observadas correlações entre a idade, a nota e o desempenho em discriminação; tampouco foram apontadas diferenças de desempenho entre os anos escolares. Conclusão Grande parte dos itens propostos para avaliação da discriminação auditiva dos sons da fala mostrou boa consistência interna em relação à tarefa. Não foi observada melhora da capacidade de discriminação auditiva dos sons da fala quanto mais velha a criança ou mais adiantado o ano escolar.


ABSTRACT Purpose Prepare a list of pseudowords in Brazilian Portuguese to assess the auditory discrimination ability of schoolchildren and investigate the internal consistency of test items and the effect of school grade on discrimination performance. Methods Study participants were 60 schoolchildren (60% female) enrolled in the 3rd (n=14), 4th (n=24) and 5th (n=22) grades of an elementary school in the city of Sao Paulo, Brazil, aged between eight years and two months and 11 years and eight months (99 to 136 months; mean=120.05; SD=10.26), with average school performance score of 7.21 (minimum 5.0; maximum 10; SD=1.23). Forty-eight minimal pairs of Brazilian Portuguese pseudowords distinguished by a single phoneme were prepared. The participants' responses (whether the elements of the pairs were the same or different) were noted and analyzed. The data were analyzed using the Cronbach's Alpha Coefficient, Spearman's Correlation Coefficient, and Bonferroni Post-hoc Test at significance level of 0.05. Results Internal consistency analysis indicated the deletion of 20 pairs. The 28 items with results showed good internal consistency (α=0.84). The maximum and minimum scores of correct discrimination responses were 34 and 16, respectively (mean=30.79; SD=3.68). No correlation was observed between age, school performance, and discrimination performance, and no difference between school grades was found. Conclusion Most of the items proposed for assessing the auditory discrimination of speech sounds showed good internal consistency in relation to the task. Age and school grade did not improve the auditory discrimination of speech sounds.


Subject(s)
Humans , Male , Female , Child , Speech Discrimination Tests/methods , Speech Disorders/diagnosis , Speech Perception/physiology , Verbal Behavior/physiology , Speech Disorders/psychology , Students , Educational Status
12.
Distúrb. comun ; 29(4): 702-710, dez. 2017. tab, ilus
Article in Portuguese | LILACS | ID: biblio-882279

ABSTRACT

Introdução: As flutuações hormonais que ocorrem normalmente durante o ciclo menstrual podem interferir no sistema auditivo. A alteração mais encontrada neste período é a diminuição da acuidade auditiva, que parece estar mais associada à flutuação dos níveis de estrogênio, quando este se encontra reduzido na fase lútea final do período menstrual. Objetivo: Investigar por meio de uma revisão sistemática a percepção auditiva de mulheres durante as fases do ciclo menstrual. Método: Foi realizada uma busca nas bases de dados eletrônicas, nacionais e internacionais, LILACS, MEDLINE, PubMed e SciELO, através da consulta pelos seguintes descritores: "percepção auditiva" AND "ciclo menstrual", "percepção de fala" AND "ciclo menstrual", "percepção de fala" AND "hormônios" e seus correspondentes na língua inglesa. Resultados: Dos 293 artigos encontrados, foram selecionados apenas 7 artigos, após os critérios de inclusão e exclusão. A caracterização da amostra dos artigos selecionados variou entre 15 a 39 mulheres, com idade variando entre 17 e 46 anos. Na maioria dos artigos, nenhum tipo de procedimento clínico para estimar as fases do ciclo menstrual foi utilizado. Foi observada a realização de testes de percepção auditiva nos sete artigos selecionados, tendo destaque os testes dicóticos. Conclusão: Há necessidade da realização de mais pesquisas sobre o assunto, exigindo-se também maior rigor metodológico na elaboração desses estudos, através de procedimentos clínicos seguros e padronizados para mensuração dos níveis hormonais.


Introduction: Hormonal fluctuations that normally occur during the menstrual cycle can interfere with the audio system. The change most found in this period is the reduction of auditory acuity, which seems to be more related to fluctuating estrogen levels, when it is reduced in the luteal phase of the menstrual period end. Objective: Investigate through a systematic review hearing in women during the menstrual cycle phases. Method: A search was made in the electronic databases, national and international, LILACS, MEDLINE, PubMed and SciELO, by consulting the following descriptors: "auditory perception" and "menstrual cycle", "speech perception" and "menstrual cycle", "speech perception" and "hormones" and their corresponding in Portuguese. Results: Twenty-two articles were found, but only 7 articles were chosen after the criteria for inclusion and exclusion. The amount of the sample of selected articles ranged between 15 and 39 women, aged between 17 and 46 years old. In most articles, any type of medical procedure to estimate the phases of the menstrual cycle was used. The performance of auditory perception tests in the seven selected articles was observed, highlighted with the dichotic tests. Conclusion: There is a need of further research on the subject, demanding a greater methodological rigor in the preparation of these studies, through clinical safe and standardized to measure hormone levels procedures.


Introducción: Las fluctuaciones hormonales que ocurren normalmente durante el ciclo menstrual puede interferir con el sistema de audio. El hallazgo más frecuente en este periodo es la reducción de la agudeza auditiva, lo que parece estar más relacionado con la fluctuación de los niveles de estrógenos, cuando se reduce en la fase lútea del final del periodo menstrual. Objetivos: Investigar a través de una revisión sistemática de la percepción auditiva de la mujer durante las fases del ciclo menstrual. Métodos: Se realizó una búsqueda en bases de datos electrónicas, nacionales e internacionales, LILACS, MEDLINE, PubMed y SciELO, mediante la consulta de los siguientes descriptores: "la percepción auditiva" Y "ciclo menstrual", "la percepción del habla" Y "ciclo menstrual", "la percepción del habla" y "hormonas" y sus homólogos en el idioma Inglés. Resultados: De los 293 artículos encontrados, se seleccionaron sólo 7 artículos, después de que los criterios de inclusión y exclusión. La caracterización de la muestra de los artículos seleccionados osciló entre 15 y 39 mujeres, con edades comprendidas entre los 17 y 46 años. En la mayoría de los artículos, cualquier tipo de procedimiento médico para estimación se utilizan las fases del ciclo menstrual. el rendimiento de la prueba de percepción auditiva se observó en los siete elementos seleccionados, resalte que tiene dicóticos. Conclusión: Existe la necesidad de más investigación sobre el tema, lo que requiere también mayor rigor metodológico en la elaboración de estos estudios, através de procedimientos clínicos segura y estandarizada para medir los niveles hormonales.


Subject(s)
Humans , Female , Adult , Auditory Perception , Databases, Bibliographic , Hormones , Menstrual Cycle , Speech Perception , Women
13.
Braz. j. otorhinolaryngol. (Impr.) ; 83(5): 574-579, Sept.-Oct. 2017. graf
Article in English | LILACS | ID: biblio-889297

ABSTRACT

Abstract Introduction: Diabetes mellitus (DM) is a chronic metabolic disorder of various origins that occurs when the pancreas fails to produce insulin in sufficient quantities or when the organism fails to respond to this hormone in an efficient manner. Objective: To evaluate the speech recognition in subjects with type I diabetes mellitus (DMI) in quiet and in competitive noise. Methods: It was a descriptive, observational and cross-section study. We included 40 participants of both genders aged 18-30 years, divided into a control group (CG) of 20 healthy subjects with no complaints or auditory changes, paired for age and gender with the study group, consisting of 20 subjects with a diagnosis of DMI. First, we applied basic audiological evaluations (pure tone audiometry, speech audiometry and immittance audiometry) for all subjects; after these evaluations, we applied Sentence Recognition Threshold in Quiet (SRTQ) and Sentence Recognition Threshold in Noise (SRTN) in free field, using the List of Sentences in Portuguese test. Results: All subjects showed normal bilateral pure tone threshold, compatible speech audiometry and "A" tympanometry curve. Group comparison revealed a statistically significant difference for SRTQ (p = 0.0001), SRTN (p < 0.0001) and the signal-to-noise ratio (p < 0.0001). Conclusion: The performance of DMI subjects in SRTQ and SRTN was worse compared to the subjects without diabetes.


Resumo Introdução: O diabetes mellitus (DM) é um distúrbio metabólico crônico de várias origens, que ocorre quando o pâncreas deixa de produzir insulina em quantidade suficiente ou quando o organismo não consegue responder a esse hormônio de maneira eficiente. Objetivo: Avaliar o reconhecimento de fala em indivíduos com diabetes mellitus tipo I (DMI) no silêncio e no ruído competitivo. Método: Estudo descritivo, observacional e transversal. Foram incluídos 40 participantes de ambos os sexos entre 18 e 30 anos, divididos em um grupo controle (GC) de 20 indivíduos saudáveis sem queixas ou alterações auditivas, pareados por idade e sexo com o grupo de estudo, composto por 20 indivíduos com diagnóstico de DMI. Inicialmente aplicou-se uma avaliação audiológica (audiometria tonal, logoaudiometria e imitanciometria) para todos os indivíduos; a seguir, os mesmos foram avaliados para o Limiar de Reconhecimento de Sentenças no Silêncio (LRSS) e Limiar de Reconhecimento de Sentenças no Ruído (LRSR), em campo livre, por meio do teste Lista de Sentenças em Português. Resultados: Todos os participantes apresentaram audiometria tonal dentro dos padrões de normalidade bilateralmente, logoaudiometria compatível e curva timpanométrica do tipo A. A comparação dos grupos revelou uma diferença estatisticamente significante para LRSS (p = 0,0001), LRSR (p < 0,0001) e a relação sinal-ruído (p < 0,0001). Conclusões O desempenho dos indivíduos com DMI para LRSS e LRSR foi pior em comparação com os indivíduos sem diabetes.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Auditory Perception , Speech Perception , Diabetes Mellitus, Type 1/physiopathology , Noise , Speech Discrimination Tests , Case-Control Studies , Cross-Sectional Studies
14.
Psicol. teor. pesqui ; 32(spe): e32ne24, 2016.
Article in Portuguese | LILACS | ID: biblio-842308

ABSTRACT

RESUMO Este estudo teve por objetivo examinar teorias contemporâneas da dislexia, com base nos achados sobre as alterações no processamento auditivo e na percepção de fala em disléxicos. A sustentação das teorias fonológica, alofônica e do déficit auditivo é discutida a partir dos achados sobre essas alterações perceptuais. É proposto um novo modelo teórico, segundo o qual a dislexia é um distúrbio multifatorial, com uma gama de sintomas comportamentais associados. O déficit apresentado pelos disléxicos é em parte linguístico, como enunciado na teoria fonológica, e em parte causado pela alteração perceptual auditiva, como prevê a teoria do déficit auditivo. Ambos os fatores interagem e são indissociáveis na explicação da sintomatologia observada no transtorno de leitura e escrita.


ABSTRACT This study aims to examine contemporary theories on dyslexia, based on findings related to changes in auditory processing and speech perception found in dyslexics. The support for the phonological, allophonic and auditory deficit theories of dyslexia is discussed based on findings related to these changes in auditory perception. A new theoretical model is proposed, according to which dyslexia is a multifactorial-based deficit, with a gamut of associated behavioral symptoms. The deficit presented by dyslexics is partially linguistic, as advocated by the phonological theory, and partially auditory, as advocated by the theory of auditory deficit. Both factors interact and are inseparable in accounting for the symptomatology observed in reading and writing disorders.

15.
Audiol., Commun. res ; 21: e1605, 2016. tab
Article in Portuguese | LILACS | ID: lil-777593

ABSTRACT

RESUMO Objetivo Avaliar o reconhecimento de fala, considerando a previsibilidade da palavra a partir de um teste elaborado. Métodos Foi realizada anamnese, testes de rastreio de comprometimento cognitivo e depressão e avaliação audiológica convencional. Foi desenvolvido um Teste de Reconhecimento de Fala utilizando Frases de Previsibilidade Alta e Baixa e aplicado a 36 idosos (G1 e G3 - grupos sem perda auditiva até 4 kHz e G2 e G4 - grupos com perda auditiva neurossensorial de grau leve a moderado). Dois grupos realizaram o teste no silêncio e com ruído (relação sinal/ruído +5 dB) e os outros dois grupos somente com ruído (relações +5 dB e 0 dB). Resultados O teste de reconhecimento de fala revelou, de modo geral, maior pontuação nas frases de previsibilidade alta e melhores desempenhos para os grupos sem perda auditiva. No silêncio, os idosos sem e com perda auditiva obtiveram pontuação máxima igual e as menores pontuações ocorreram na condição de ruído mais intenso. O benefício da previsibilidade foi positivo para os grupos 1, 2 e 3. O grupo 4 apresentou comportamento variado quanto ao uso da previsibilidade (ora positivo, ora negativo). Conclusão Com a população de idosos avaliados e as diferenças observadas em um dos grupos considerados, não foi possível compreender, com exatidão, como os idosos se beneficiam do apoio da previsibilidade. A perda auditiva e a presença do ruído influenciaram negativamente o desempenho no teste. Faz-se necessária a continuidade desta linha de pesquisa para determinar a validade do material elaborado.


ABSTRACT Purpose evaluation of the speech recognition concerning the word predictability based on a developed test. Methods 1 Results In general, Speech recognition test showed a higher score in the high predictability sentences and better performance for groups without hearing loss. In the silence, elderly with and without hearing loss have also obtained high scores and the lowest scores were achieved in situations with most intense noise. The benefit of predictability was positive for groups 1, 2 and 3. Group 4 showed a different behavior towards the use of predictability (sometimes positive or negative). Conclusion For the elderly evaluated and the differences observed in one of the groups, it was not possible to precisely determine how the elderly benefit from predictability. The hearing loss and the noise have negatively influenced the test performance. Further researches in the area are necessary to confirm the validity of the material produced.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Presbycusis/diagnosis , Speech Discrimination Tests , Speech Perception , Cognitive Aging , Hearing Loss, Sensorineural/diagnosis , Speech Recognition Software
16.
CoDAS ; 26(5): 367-373, 2014. tab, graf
Article in English | LILACS | ID: lil-727060

ABSTRACT

Purpose: To analyze the presence of auditory cortical potential and its correlation with psychoacoustic detection of speech sounds as well as the latency of the P1, N1 e P2 components presented in free field in hearing impaired adults with and without amplification. Methods: We evaluated 22 adults with moderate to severe symmetrical bilateral sensorineural hearing loss, regular users of bilateral hearing aids. Speech sounds of low (/m/), medium (/g/) and high (/t/) frequencies were presented in sound field in decreasing intensities of 75, 65 and of 55 dBSPL in free field with and without hearing aids. The used equipment performs automatic statistical detection of the presence of response; forthermore, the latencies of waves P1, N1 e P2 were labeled and the psychoacoustic perception was registered. Results: The results demonstrated the increased presence of cortical response with hearing aids. We observed the correlation between psychoacoustic perception and automatic detection of 91% for the sounds /g/ and /t/ and ranged from 73 to 86% for the sound /m/. The averages of latencies P1-P2-N1 decreased with both increasing intensity and the use of hearing aids for the three sounds. The differences were significant for the sounds /g/ and /t/ in comparison with and without hearing aids. Conclusion: There was increase in the presence of cortical auditory evoked potential with hearing aids. Automatic detection of cortical response provided with hearing aids showed 91% agreement with the psychoacoustic perception of the speech signal. In the analysis of latency measures of the P1, N1 and P2 components, it was observed a decrease with the increase of the signal intensity and the use of amplification for the three speech stimuli /m/, /g/ and /t/.


Objetivo: Analisar a presença do potencial auditivo cortical e sua concordância com a detecção psicoacústica de sons de fala bem como a latência dos componentes P1, N1 e P2 apresentados em campo livre em adultos deficientes auditivos com e sem o uso da amplificação. Métodos: Foram avaliados 22 adultos com perda auditiva sensorioneural bilateral simétrica de grau moderado a severo, usuários regulares de prótese auditiva bilateral. Foram utilizados estímulos de fala de baixas (/m/), médias (/g/) e altas (/t/) frequências, apresentados em intensidades decrescentes de 75, 65 e 55 dBNPS em campo livre nas condições sem e com o uso de próteses auditivas. O equipamento utilizado realiza a detecção estatística automática da resposta; além disso, as latências das ondas P1, N1 e P2 foram marcadas e a percepção psicoacústica foi registrada. Resultados: Os resultados demonstraram o aumento da presença de resposta cortical na condição com prótese auditiva. Observou-se a concordância entre a percepção psicoacústica e a detecção automática de 91% para os sons /g/ e /t/ e variou de 73 a 86% para o som /m/. As médias das latências P1, N1 e P2 diminuíram tanto com o aumento da intensidade como com o uso da prótese auditiva para os três sons de fala. As diferenças foram significantes para os sons /g/ e /t/ na comparação sem e com prótese auditiva. Conclusão: Houve aumento da presença do potencial evocado auditivo cortical na condição com prótese auditiva. A detecção automática da presença de resposta cortical na condição com prótese auditiva apresentou 91% de concordância com a percepção psicoacústica do sinal de fala. Na análise das medidas de latência dos componentes P1, N1 e P2, observou-se a uma diminuição tanto com o aumento da intensidade do sinal como com o uso da amplificação para os três estímulos de fala /m/, /g/ e /t/.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Auditory Perception , Evoked Potentials, Auditory , Speech Perception , Auditory Threshold , Acoustic Stimulation/methods , Brazil , Hearing Aids , Hearing Loss, Sensorineural , Severity of Illness Index
17.
Distúrb. comun ; 24(3)dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-663183

ABSTRACT

Introdução: Carhart defi ne a logoaudiometria como uma técnica onde amostras de fala padronizadas são utilizadas para medir a habilidade de reconhecer palavras. Uma das formas de se ?padronizar? esse procedimento seria o uso de listas de palavras gravadas no teste de IRF( Índice de reconhecimento de fala). Objetivo: comparar o desempenho de pacientes no teste de logoaudiometria monitorada a viva voz e na logoaudiometria gravada em compact disc. (CD). Material e Método: estudo prospectivo transversal cuja casuística foi composta por 43 indivíduos, (85 orelhas). Todos foram submetidos à pesquisa do Índice de Reconhecimento de Fala (IRF) à viva voz e por material gravado. Os participantes foram examinados em ordem diferente de apresentação Resultados: Não houve diferença estatisticamente significante aoanalisar a ordem de apresentação das palavras (viva voz X gravação). A análise da concordância entre os resultados de um mesmo paciente nas duas condições mostrou que houve diferença estatisticamente significante (p < 0,001), ou seja, em 64,7%, o resultado foi melhor para uso do método de IRF gravado. Conclusão: os resultados mostraram que o desempenho dos pacientes no teste de IRF gravada é melhor do que para o teste à viva voz. Recomenda-se o uso de material gravado para melhorar a qualidade do teste do índice de reconhecimento de fala...


Introduction: Carhart defi nes speech audiometry as a technique where standardized speech samples are used to measure the ability to recognize words. One way to ?standardize? this procedure is the use of lists of recorded words. The aim of this study is to compare the performance of a group of subjects at the speech recognition index for monitored live voice and recorded speech audiometry. Method: prospective transversal study of a sample composed by 43 individuals (85 ears). All were tested for theSpeech Recognition Index (SRI) for both ways of presentation: monitored live voice and recorded speech. Participants were examined in a different order of presentation Results: No statistically signifi cant difference was found when considering the order of presentation of words (live voice x recorded speech). Analysis of agreement between the results of the same patient in both conditions showed a statistically significant difference (p<0.001), meaning that in 64.7%, the result was different. Conclusion: The results showed that patients? performance in speech recognition index for recorded speech is better than with monitored live voice. It is recommended the use of recorded material to improve the quality of speech audiometry test...


Introducción: Carhart logoaudiometría defi ne como una técnica en muestras estandarizadas discurso se utilizan para medir la capacidad de reconocer las palabras. Una forma de ?normalizar? este procedimiento es el uso de listas de palabras registradas. Objetivo: Comparar la prueba de rendimiento en los pacientes monitorizados audiometría del habla viva voz y audiometría vocal grabada en disco compacto. (CD). Material y métodos: Estudio transversal prospectivo, cuya muestra estuvo compuesta por 43 personas (85 orejas). Todos fueron evaluados por el Índice de reconocimiento de voz (SRI) y la voz viva de metraje. Los participantes fueron examinados en un orden diferente de la Presentación. Resultados: No hubo diferencias estadísticamente signifi cativas al analizar el orden de presentación de las palabras (X en directo la grabación de voz). El análisis de concordancia entre los resultados de la misma paciente, tanto en condiciones mostró que había una diferencia estadísticamente significativa(p <0,001), es decir, el 64,7%, el resultado fue diferente. Conclusión: Los resultados mostraron que el rendimiento de los pacientes en la prueba de audiometría del habla registrado es mejor que poner a prueba el altavoz. Se recomienda el uso de material grabado para mejorar la calidad del reconocimiento del habla índice de prueba...


Subject(s)
Humans , Audiology , Audiometry, Speech , Hearing , Speech Perception , Speech, Language and Hearing Sciences
18.
Distúrb. comun ; 21(2): 229-238, ago. 2009. tab, ilus
Article in Portuguese | LILACS | ID: biblio-1417744

ABSTRACT

Introdução: O Implante coclear (IC) é um recurso de estimulação elétrica que é utilizado unilateralmente, o que gera algumas dificuldades para o paciente. Os usuários de IC que apresentam resíduo auditivo no ouvido não implantado (ouvido contra-lateral ao IC) poderiam ter beneficio da amplificação neste ouvido. Objetivo: Avaliar os benefícios do uso do Aparelho de Amplificação Sonora Individual (AASI) no ouvido não implantado. Método: Estudo prospectivo no qual 14 crianças com deficiência auditiva neurossensorial bilateral severa, e severa a profunda e profunda, usuárias de IC foram submetidas a nova avaliação audiológica e adaptação do AASI. Após um mês de uso efetivo do AASI com o IC foi realizada avaliação do uso combinado do IC com o AASI e após uma semana de uso apenas do IC, a avaliação só com o IC. Foi aplicado o questionário PEACH aos pais e avaliada nas crianças o reconhecimento de palavras dissílabas no silêncio e na relação S/R + 10 dB com IC e com o IC mais o AASI. Resultados: A análise estatística não mostrou diferença significante entre as condições com IC mais AASI e apenas IC. Conclusão: Não houve diferenças estatísticas entre as condições avaliadas, mas é recomendável uma avaliação individual dos benefícios dos aparelhos de amplificação sonora individual.


Introduction: The cochlear implant (CI) is an electrical stimulation feature that is used unilaterally, which ends up creating some difficulties for the patient. CI (cochlear implant) users presenting auditory residue in the non-implanted ear could benefit from amplification in this ear. Aim: To evaluate the hearing aid (HA) use benefits in the non-implanted ear. Methods: A prospective study in which 14 children with bilateral sensory-neural severe, severe and profound and profound hearing impairment, users of the new CI (cochlear implant), were submitted to the audiological assessment and adaptation of HA. After one month of effective use of the HA (hearing aid) with the CI(cochlear implant), a hearing evaluation of the use of CI(cochlear implant) combined with the HA (hearing aid) was held, and after only one week of IC (cochlear implant) use, the assessment only with the CI(cochlear implant) was performed. The children's parents filled-in the PEACH survey, the recognition of two-syllable words in silence was evaluated and in S/R relationship + 10dB exclusively with the CI(cochlear implant) and with the CI (cochlear implant) plus HA (hearing aid). Results: The statistical analysis did not show any significant difference between the conditions with CI(cochlear implant) plus HA (hearing aid) and only CI (cochlear implant). Conclusion: There were no significant statistical differences under the evaluated conditions, but an assessment of the individual benefits of the HA (Hearing Aid) is recommended.


Introducción: El implante coclear (IC) es un recurso de estimulación eléctrica que se utiliza de manera unilateral, lo que crea algunas dificultades para el paciente. Los usuarios de IC (implante coclear) que presentan residuos auditivos en el oído non implantado podrían beneficiarse de la amplificación en este oído. Objetivo: Evaluar los beneficios de la utilización de audifono individual en el oído no implantado. Metodología: Estudio prospectivo en que 14 niños con discapacidad auditiva neurosensorial bilateral grave, graves y profundos y profundos, usuarios de IC, han sido objeto de nueva evaluación audiológica y a adaptación de audifono. Después de un mes de uso efectivo del audifono con el IC fue realizada evaluación del uso combinado del IC con audifono y después de una semana de uso sólo la IC, la evaluación sólo con el IC. Se aplico el cuestionario PEACH a los padres, y se evaluó en los niños el reconocimiento de palabras bisílabas en silencio y en la relación S/R + 10 dB con IC y con IC más el audifono. Resultados: El análisis estadístico no mostró diferencias significativas entre las condiciones con IC más audifono y sólo IC. Conclusión: No hubo diferencias estadísticas entre las condiciones evaluadas, pero es recomendable una evaluación individual de los beneficios de un audifono.


Subject(s)
Humans , Child, Preschool , Child , Cochlear Implantation , Hearing Aids , Hearing Loss, Sensorineural/therapy , Parents , Speech Perception , Retrospective Studies , Communication Aids for Disabled , Controlled Before-After Studies
19.
Distúrb. comun ; 20(1): 77-96, abr. 2008. tab, graf
Article in Portuguese | LILACS | ID: lil-531674

ABSTRACT

Objetivo: investigar a qualidade e o concenso entre examinadores do uso de roteiro baseado no modelo fonético de descrição da qualidade vocal (VPAS, 2000). Métodos: 14 juízes foram selecionados e participaram de um curso de 20 horas de duração em análise fonética da qualidade vocal, no qual analisaram os registros de voz de 2 falantes por meio do VPAS-etapa 1 (identificação de presença/ausência de ajustes). Seus julgamentos foram comparados aos de dois examinadores experientes no roteiro (adotados como referência), a partir dos quais foi composto um grupo de sete (7) examinadores para a etapa 2 (graduação dos ajustes presentes em escala de 1 a 6). Os juízes participantes da 2 também responderam a um questionário. Os dados foram analisados quanto à comparação dos julgamentos e respostas ao questionário dos juízes do grupo estudado. Resultados: os resultados foram apresentados e distribuídos em relação à fundamentação e aplicabilidade do roteiro, apontando, em ordem decrescente, concenso par aos grupos de ajustes supralaríngeos transversais, longitudinais, velofaríngeos e fonatórios. Conclusão: a validade de aplicação de modelo de descrição fonética da qualidade vocal foi reforçada bem como a necessidade de maior aprofundamento na formação de juízes para uso do roteiro VPAS.


Subject(s)
Humans , Male , Female , Adult , Speech Perception , Voice , Voice Disorders , Voice Quality
20.
Distúrb. comun ; 19(3): 343-355, 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-501825

ABSTRACT

A deficiência de audição impõe dificuldades sobre a percepção e a produção de contrastes de fala, uma vez que pistas acústicas relevantes podem ficar distorcidas ou não disponíveis, resultando em alterações relacionadas ao modo de articulação, ponto de articulação e ao vozeamento. O objetivo deste trabalho foi expandir o conhecimento sobre a percepção e a produção do contraste de vozeamento estudando dois sujeitos com deficiência de audição de grau moderadamente severo e configuração descendente. Os parâmetros acústicos considerados foram a duração da consoante e o Voice Onset Time (VOT). Foi utilizado um corpus de seis palavras, iniciadas por uma das 6 oclusivas, inseridas em frase- veículo. Para a análise perceptiva das produções foram realizadas duas tarefas de identificação das oclusivas por 120 sujeitos sem queixas auditivas. Os resultados da análise perceptiva mostraram alto índice de acerto. Na análise acústica, encontramos, para S1, resultados compatíveis com a literatura, com diferenças significativas nas medidas de duração e VOT entre os pares que contrastam pelo vozeamento. Para S2, os valores de duração também se mostraram diferentes, de acordo com o contraste de vozeamento, com valores de duração maiores para as não vozeadas se comparadas com os pares vozeados. Com relação ao VOT, encontramos valores positivos para as não vozeadas. Para os sons vozeados foi observado que o pré-vozeamento apresentou descontinuidades, ou seja, a medida da barra de sonoridade não coincidiu com a duração da oclusão. Os dois sujeitos estudados implementam com eficiência o contraste de vozeamento e também o discriminam auditivamente


Subject(s)
Humans , Male , Female , Adolescent , Auditory Perceptual Disorders , Persons With Hearing Impairments , Speech Perception , Voice , Case Reports
SELECTION OF CITATIONS
SEARCH DETAIL